Spesifikasi
range | EasyPact | |
---|---|---|
product name | EasyPact TVS | |
product or component type | Differential thermal overload relay | |
device short name | LRE | |
relay application | Motor protection | |
phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1 |
product compatibility | LC1E300...630 | |
---|---|---|
network type | AC | |
network frequency | 50...60 Hz | |
mounting support | Under contactor Plate | |
thermal overload class | Class 10A conforming to IEC 60947-4-1 | |
signalling function | Relay trip indicator | |
thermal protection adjustment range | 259…414 A | |
tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 | |
mechanical robustness | Shocks: 6 Gn for 11 ms conforming to IEC 60068-2-7 Vibrations: 3 Gn conforming to IEC 60068-2-6 | |
auxiliary contact composition | 1 NO + 1 NC | |
[Ith] conventional free air thermal current | 5 A for signalling circuit | |
[Ue] rated operational voltage | <= 690 V AC | |
associated fuse rating | 400 A aM for power circuit 500 A gG for power circuit 5 A gG for signalling circuit | |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 | |
[Uimp] rated impulse withstand voltage | 6 kV | |
local signalling | Trip indicator | |
control type | Push-button red stop: Push-button green reset: | |
temperature compensation | -20…60 °C | |
connection pitch | 48 mm | |
connections - terminals | Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: solid without cable end Power circuit: lugs Power circuit: bars - busbar cross section: 4 x 25 mm | |
Recommended tightening torque | Power circuit: 35 N.m - on bars M10 Power circuit: 35 N.m - on lugs M10 Signalling circuit: 1.7 N.m - on screw clamp terminals | |
height | 134 mm | |
width | 180 mm | |
depth | 134 mm | |
net weight | 2.4 kg |
standards | IEC 60947-5-1 IEC 60947-4-1 | |
---|---|---|
product certifications | EAC | |
protective treatment | TH conforming to IEC 60068 | |
IP degree of protection | IP00 conforming to IEC 60529 | |
ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 -20…70 °C with derating | |
ambient air temperature for storage | -60…80 °C | |
fire resistance | 850 °C conforming to IEC 60068-2-1 | |
dielectric strength | 6 kV at 50 Hz conforming to IEC 60255-5 | |
electromagnetic compatibility | Surge withstand: 6 kV conforming to IEC 60801-5 |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 2.9 kg | |
Package 1 Height | 16 cm | |
Package 1 width | 17.5 cm | |
Package 1 Length | 27.2 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
REACh free of SVHC | Yes | |
EU RoHS Directive | Compliant EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | ||
Environmental Disclosure | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Filter By
range | EasyPact | |
---|---|---|
product name | EasyPact TVS | |
product or component type | Differential thermal overload relay | |
device short name | LRE | |
relay application | Motor protection | |
phase failure sensitivity | Tripping current 130 % of Ir on two phase, the last one at 0 conforming to IEC 60947-4-1 |
product compatibility | LC1E300...630 | |
---|---|---|
network type | AC | |
network frequency | 50...60 Hz | |
mounting support | Under contactor Plate | |
thermal overload class | Class 10A conforming to IEC 60947-4-1 | |
signalling function | Relay trip indicator | |
thermal protection adjustment range | 259…414 A | |
tripping threshold | 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1 | |
mechanical robustness | Shocks: 6 Gn for 11 ms conforming to IEC 60068-2-7 Vibrations: 3 Gn conforming to IEC 60068-2-6 | |
auxiliary contact composition | 1 NO + 1 NC | |
[Ith] conventional free air thermal current | 5 A for signalling circuit | |
[Ue] rated operational voltage | <= 690 V AC | |
associated fuse rating | 400 A aM for power circuit 500 A gG for power circuit 5 A gG for signalling circuit | |
[Ui] rated insulation voltage | 690 V conforming to IEC 60947-4-1 | |
[Uimp] rated impulse withstand voltage | 6 kV | |
local signalling | Trip indicator | |
control type | Push-button red stop: Push-button green reset: | |
temperature compensation | -20…60 °C | |
connection pitch | 48 mm | |
connections - terminals | Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible without cable end Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Signalling circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: solid without cable end Power circuit: lugs Power circuit: bars - busbar cross section: 4 x 25 mm | |
Recommended tightening torque | Power circuit: 35 N.m - on bars M10 Power circuit: 35 N.m - on lugs M10 Signalling circuit: 1.7 N.m - on screw clamp terminals | |
height | 134 mm | |
width | 180 mm | |
depth | 134 mm | |
net weight | 2.4 kg |
standards | IEC 60947-5-1 IEC 60947-4-1 | |
---|---|---|
product certifications | EAC | |
protective treatment | TH conforming to IEC 60068 | |
IP degree of protection | IP00 conforming to IEC 60529 | |
ambient air temperature for operation | -20…60 °C without derating conforming to IEC 60947-4-1 -20…70 °C with derating | |
ambient air temperature for storage | -60…80 °C | |
fire resistance | 850 °C conforming to IEC 60068-2-1 | |
dielectric strength | 6 kV at 50 Hz conforming to IEC 60255-5 | |
electromagnetic compatibility | Surge withstand: 6 kV conforming to IEC 60801-5 |
Unit Type of Package 1 | PCE | |
---|---|---|
Number of Units in Package 1 | 1 | |
Package 1 Weight | 2.9 kg | |
Package 1 Height | 16 cm | |
Package 1 width | 17.5 cm | |
Package 1 Length | 27.2 cm |
Sustainable offer status | Green Premium product | |
---|---|---|
REACh Regulation | ||
REACh free of SVHC | Yes | |
EU RoHS Directive | Compliant EU RoHS Declaration | |
Toxic heavy metal free | Yes | |
Mercury free | Yes | |
RoHS exemption information | ||
China RoHS Regulation | ||
Environmental Disclosure | ||
WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Recently Viewed Products
Schneider EasyPact TVS differential thermal overload relay 259...414 A - class 10A
Rp 8,304,931.00
Rp 5,162,344.00